Lactate Dehydrogenase (LDH) Activity Assay Kit

Catalogue Number: E-BC-K046-M-ELA

Manufacturer:Elabscience
Shelf Life:6 months
Type:Enzyme Assays
Shipping Condition:Blue Ice
Storage Condition:2-8°C
Unit(s): 96 T, 500 assays
Range: 6-1000 U/L
Sensitivity: 6 U/L
Sample type: Cells, Plasma, Serum, Tissue
Sample size:

Description

Description: Application This kit can be used to measure Lactate dehydrogenase (LDH) activity in tissues, serum (plasma), hydrothorax, culture cells, cell culture supernatants and other samples. Detection significance Lactate dehydrogenase (LDH or LD) is an enzyme found in nearly all living cells (animals, plants, and prokaryotes). LDH catalyzes the conversion of lactate to pyruvic acid and back, as it converts NAD+ to NADH and back. A dehydrogenase is an enzyme that transfers a hydride from one molecule to another. LDH is expressed extensively in body tissues, such as blood cells and heart muscle. Because it is released during tissue damage, it is a marker of common injuries and disease such as heart failure. Lactate dehydrogenase is composed of four subunits (tetramer). The two most common subunits are the LDH-M and LDH-H protein, encoded by the LDHA and LDHB genes, respectively. These two subunits can form five possible tetramers (isoenzymes): 4H, 4M, and the three mixed tetramers (3H1M, 2H2M, 1H3M). These five isoforms are enzymatically similar but show different tissue distribution: The major isoenzymes of skeletal muscle and liver, M4, has four muscle (M) subunits, while H4 is the main isoenzymes for heart muscle in most species, containing four heart (H) subunits. Detection principle Coenzyme I as a hydrogen carrier, LDH catalyzes the production of pyruvic acid from lactic acid, and pyruvic acid react with pyruvic acid to form pyruvate dinitrophenylhydrazone which is brownish red in alkaline solution. The depth of the color is proportional to the concentration of pyruvic acid. The activity of LDH can be measured indirectly by measuring the OD value at 450 nm. Experimental instrument Microplate, Micropipettor, Vortex mixer, Water bath, Microplate reader (450 nm) Sample preparation 1. Serum (plasma): Detect the sample directly. For plasma sample, heparin is recommended as an anticoagulant. 2. Tissue samples: Accurately weigh the tissue, add 9 times the volume of PBS (0.01 M, pH 7.4) according to the ratio of Weight (g): Volume (mL) =1:9. Homogenize the tissue sample with homogenizer on ice. Centrifuge the homogenized tissue at 10000xg for 10 min, then take the supernatant and preserve it on ice for detection. Meanwhile, determine the protein concentration of supernatant (E-BC-K318, E-BC-K168, E-BC-K165). 3. Cells sample: Collect the 1x106 cells, add 0.3-0.5 mL of PBS (0.01 M, pH 7.4). Homogenize the cells sample with homogenizer on ice. Centrifuge the homogenized cells at 10000xg for 10 min, then take the supernatant and preserve it on ice for detection. Meanwhile, determine the protein concentration of supernatant (E-BC-K318, E-BC-K168, E-BC-K165). 4. Hydrothorax sample: Collect the fresh hydrothorax to the tubes with anticoagulant (heparin is recommended as an anticoagulant) and mix fully. Centrifuge the sample at 10000xg for 10 min, then take the supernatant and preserve it on ice for detection. [Note] 1) Do not use hemolytic samples. 2) Oxalate should not be used as an anticoagulant because it will inhibit the activity of LDH. 3) The sample should be store at -20°C or -70°C if it cannot be detected in time. Operation steps 1. Blank well: add 25 µL of double distilled water. Standard well: add 5 µL of double distilled water and 20 µL of 0.2 µmol/mL pyruvic acid standard application solution. Sample well: add 20 µL of Sample. Control well: add 5 µL of double distilled water and 20 µL of sample. 2. Add 25 µL of Substrate buffer to each well. 3. Add 5 µL of Coenzyme I application solution to sample wells. 4. Mix fully and incubate at 37°C for 15 min. 5. Add 25 µL of Chromogenic agent to each well. Mix fully and incubate at 37°C for 15 min. 6. Add 250 µL of Reagent 4 application solution to each well. 7. Mix fully and stand at room temperature for 5 min. Measure the OD values of each well with Microplate Reader at 450 nm. Note: The following operating table could be as a reference. Note: (1) Do not add coenzyme I in the control well. (2) Follow the manual operation strictly. Do not add coenzyme I before adding substrate buffer. Reference for sample volume: For 0.01% mouse brain tissue homogenate, 5~20 µL (determine the volume of sample according to the sample activity). For 10% human serum dilution, 10~30 µL (determine the volume of sample according to the sample activity). Dilute the sample with saline before measurement if the LDH activity in the sample is too high. Technical parameters 1. The sensitivity of the kit is 6 U/L. 2. The detection range of the kit is 6-1000 U/L. 3. The intra-assay CV is 1.8 % and the inter-assay CV is 2.4 %. 4. The recovery of the kit is 98 %. Notes 1. This kit is for research use only. 2. Please progress strictly with operation procedures. 3.

Additional Text

2-8°C

Price
£96.00


Find out about delivery

SUPPORT

outstanding technical support

PRODUCT

we offer a full product guarantee

DELIVERY

we offer free delivery to UK universities and non profit organisations